IBM Support

WebSphere Application Server: Service integration bus fails to assign BootstrapBasicMessaging as the default chain name when the name is either not specified or is incorrect

Troubleshooting


Problem

There are two types of predefined outgoing chains used in service integration bus, namely BootstrapBasicMessaging and BootstrapSecureMessaging. When a chain name is not specified in the Provider endpoints property of the connection factory properties, the service integration bus defaults to either BootstrapBasicMessaging or BootstrapSecureMessaging based on the security settings. The problem occurs when an incorrect chain value is assigned as a default value; for example, BootstrapBasicMessaging is assigned as the default chain value instead of BootstrapSecureMessaging.

Resolving The Problem

If the chain name is not specified in the Provider endpoints property or if the default chain name specified is not correct, then you must specify the correct chain name in the Provider endpoints property.

The provider endpoint value must be specified in the following format:
hostname:7278:BootstrapBasicMessaging

In this example, hostname is the host name, 7278 is the port number, and BootstrapBasicMessaging is the chain name.

For more information about how the service integration bus assigns a default chain name for a given configuration, see http://pic.dhe.ibm.com/infocenter/wasinfo/v8r5/index.jsp?topic=/com.ibm.websphere.express.iseries.doc/ae/SIBJMSConnectionFactory_DetailForm.html.

[{"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"Not Applicable","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF012","label":"IBM i"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"},{"code":"PF035","label":"z\/OS"}],"Version":"8.5.5","Edition":"Base;Express;Network Deployment","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
15 June 2018

UID

swg21638236