APAR status
Closed as program error.
Error description
The XSLT profile timer values should be shown in milliseconds, but are shown with sub-microsecond resolution.
Local fix
Problem summary
Affected are customers making use of DataPower Stylesheet Profiling. Time values in Stylesheet Profile Status Provider were incorrectly not reported in milliseconds. There was a problem in the scaling function. The corrective factors (without the fix) are: 0.000278 (for 9003) 0.000354 (for 9004) So for a reported Time value "x" the time in milliseconds can be calculated as "x * 0.000354" for a 9004.
Problem conclusion
The fix is available in 3.8.0.12, 3.8.1.11 and 3.8.2.3
Temporary fix
Comments
APAR Information
APAR number
IC74751
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
380
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-02-28
Closed date
2011-04-15
Last modified date
2011-06-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R380 PSY
UP
R381 PSY
UP
R382 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]