APAR status
Closed as documentation error.
Error description
If an existing table is modified from column type INT or SMALLINT to SERIAL no validation is done for the existing values. The definition of SERIAL is INT+1 and the smallest values is 1. The value 0 does not exist in type SERIAL, but it can exist in INT and SMALLINT.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Informix 12.10 * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * See Problem Conclusion * ****************************************************************
Problem conclusion
The database server does not validate the values when you convert a column from an INT or SMALLINT data type to a SERIAL, SERIAL8, or BIGSERIAL column. For example, although 0 is a valid value for an INT or SMALLINT column, it is not a valid value for a serial data type column.
Temporary fix
Comments
APAR Information
APAR number
IT03438
Reported component name
INFORMIX SERVER
Reported component ID
5725A3900
Reported release
C10
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-07-28
Closed date
2015-10-16
Last modified date
2015-10-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: