IBM Support

IT01051: THE LOWER FUNCTION IN A QUERY AGAINST A UTF8 DATABASE CAN FAIL WITH ERROR -941 WHEN ANOTHER ESQL/C PROGRAM IS ACCESSING THE DATA

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When running a query that includes the LOWER function against a
    UTF8 database, the -941 error can occur if there is another
    ESQL/C program is connected to the server at the same time and
    the number of CPU VP's is set to more than 1.
    
    The error does not occur if one of the following is true:
     - the database is created in en_US locale
     - the ESQL/C program is not running at the same time.
     - the number of CPU VP's is set to 1
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Update to IDS-12.10.xC4                                      *
    ****************************************************************
    

Problem conclusion

  • Problem Fixed In IDS-12.10.xC4
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT01051

  • Reported component name

    INFORMIX SERVER

  • Reported component ID

    5725A3900

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-04-15

  • Closed date

    2015-10-16

  • Last modified date

    2024-09-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INFORMIX SERVER

  • Fixed component ID

    5725A3900

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
24 September 2024