Error description
Consider a simple table using a functional index in a definition like this create table "informix".kokos (a serial not null ,b varchar(40)); create function "informix".uppc (a varchar (40)) returning varchar (40) with (not variant); return upper (a); end function; create index "informix".kokos_1 on "informix".kokos ("informix".uppc(b) ) using btree ; A simple standalone query like: select a,b,uppc (b) from kokos where uppc (b) like uppc ("Hqs%"); ... will use the index, but the similar query in a stored procedure create procedure "informix".jojo1 (p_b varchar (40)) returning integer, varchar (40), varchar(40); define l_a integer; define l_b varchar (40); define l_ub varchar (40); foreach select a,b,uppc(b) into l_a,l_b,l_ub from kokos where uppc (b) like uppc (p_b) return l_a, l_b,l_ub with resume; end foreach end procedure; execute procedure jojo1 ("Hqs%"); ... will not use the index, but can be forced by a directive. And then the statistics show inaccurately that the index is used, yet all rows in the table are scanned.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 12.10.xC15 and 14.10.xC4. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 12.10.xC15 (when available) or * * 14.10.xC4. * ****************************************************************
Problem conclusion
Fixed in Informix Server 12.10.xC15 and 14.10.xC4.
Temporary fix
Comments
APAR Information
APAR number
IT31791
Reported component name
INFORMIX SERVER
Reported component ID
5725A3900
Reported release
C10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-02-07
Closed date
2020-12-10
Last modified date
2024-09-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INFORMIX SERVER
Fixed component ID
5725A3900
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
25 September 2024