IBM Support

IT31447: API CONNECT TEST TOOL MAY FAIL TO TEST API IF MULTIPLE API'S HAVE THE SAME PATH

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When multiple API's match the same path the test tool may fail
    to route the request resulting in CORS errors observed from the
    test tool and being unable to test from the test tool.
    
    In such circumstances the API should still work when you invoke
    from another client (eg. CURL, POSTMAN, etc)
    
    The three criteria to trigger this issue are:
       1.More than one API candidates are matched for the incoming
    request.
    
       2.All these candidates are configured with security
    requirements.
    
       3.Using the test tool from the browser, which will trigger
    the OPTIONS HTTP request (the CORS preflight request) WITHOUT
    security related headers.
    

Local fix

Problem summary

  • Unexpected API routing error "Cannot pass the client
    identification check that is required by the target API or
    operation." when testing APIs in developer portal
    

Problem conclusion

  • The fix is in 2018.4.1.9
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT31447

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    18X

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-01-08

  • Closed date

    2020-01-08

  • Last modified date

    2020-01-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

  • R18X PSY

       UP

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"18X"}]

Document Information

Modified date:
27 September 2021