APAR status
Closed as program error.
Error description
If the IBM MQ Appliance is configured without a system name, an FDC containing probe ID DP016021will be generated once a minute.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: This issue affects users of the IBM MQ Appliance who have loaded MQ V9.1.0.3 firmware onto their appliance. Platforms affected: MultiPlatform **************************************************************** PROBLEM DESCRIPTION: The IBM MQ Appliance periodically checks to see if any HA functionality needs to be restarted. If an MQ Appliance was not configured for HA and the appliance system name was left blank during the startup wizard, then this check would result in an FDC containing probe identifier DP016021 being generated. An excerpt from the FDC is shown below: *********************************************************** Probe ID: DP016021 Probe Type: INCORROUT Probe Severity: 4 Probe Description: AMQ6125E: An internal IBM MQ Appliance error has occurred. FDCSequenceNumber: 0 Arith1:- 89 (0x59) Comment1: Failed running /opt/mqm/bin/startHAifDead ***********************************************************
Problem conclusion
The IBM MQ Appliance has been updated to no longer generate an FDC if the check to see if the HA functionality needs to be restarted is performed on a system that has not been enabled for HA. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v9.1 CD 9.1.5 v9.1 LTS 9.1.0.5 The latest available maintenance can be obtained from 'WebSphere MQ Recommended Fixes' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037 If the maintenance level is not yet available information on its planned availability can be found in 'WebSphere MQ Planned Maintenance Release Dates' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT30637
Reported component name
MQ APPLIANCE M2
Reported component ID
5737H4700
Reported release
910
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-10-17
Closed date
2019-10-24
Last modified date
2019-10-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MQ APPLIANCE M2
Fixed component ID
5737H4700
Applicable component levels
R910 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS5K6E","label":"IBM MQ Appliance"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"910","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]
Document Information
Modified date:
24 October 2019