A fix is available
APAR status
Closed as program error.
Error description
TAM object might cause a hang of the DataPower device and watchdog(reload) unexpectedly. The issue can occur on startup of the device or domain.
Local fix
Disable TAM objects and save configuration. After device has all domains running or domain is reloaded, enable TAM object. Do not save the configuration on TAM enablement or the TAM objects will be re-enabled for a subsequent reload of the domain/device which will put it back into the same bad behavior.
Problem summary
Fix will prevent the deadlock when TAM is starting.
Problem conclusion
Fix is available in 2018.4.1.8 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT30022
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
18X
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-08-23
Closed date
2019-10-11
Last modified date
2019-10-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R18X PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"18X"}]
Document Information
Modified date:
28 September 2021