A fix is available
APAR status
Closed as program error.
Error description
In the event that an import is done which brings up a standby-control object that happens to have a NULL or invalid VIP (such as 127.0.0.1) it is then possible for the import to cause a reload when committing that standby-control object.
Local fix
Change the VIP to use an appropriate value that is not NULL. (As well as avoid importing a default domain due to the network configuration behavior becoming unexpected)
Problem summary
The fix will prevent the DataPower from restarting if the interface for the standalone interface does not have an IPv4 address configured.
Problem conclusion
The fix will be in 2018.4.1.9
Temporary fix
Comments
APAR Information
APAR number
IT29556
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
18X
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-06-26
Closed date
2019-12-03
Last modified date
2019-12-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R18X PSY
UP