Error description
Error Description: After restarting the Sterling B2B Integrator, which is a clustered environment with two adapter containers per node, the external connections to the adapter container that hosts the SFTP Server adapter are timing out.
Local fix
STRRTC - 576617 SB / SB Circumvention: Restart the node (sometimes multiple times) until the connections are established.
Problem summary
Users Affected: SFTP Server Adapter users in Containers Problem Description: Trading partners unable to retrieve files from the SFTP Server adapter running on adapter container after cluster restart or DR Failover. Platforms Affected: All
Problem conclusion
Resolution Summary: A code fix is provided. Delivered In: 5020603_11
Temporary fix
Shutdown the SFTP server adapters before a restart and bring them back up after the adapater container is back up.
Comments
APAR Information
APAR number
IT28934
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
525
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-05-01
Closed date
2019-08-20
Last modified date
2019-09-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.5","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
03 September 2019