APAR status
Closed as program error.
Error description
After upgrading IBM Sterling B2B Integrator to V5.2.6.3_9 the SFTP client receives "Error bad sigbloblen 48 != SIGBLOB_LEN" when connecting to the SFTP Server adapter. You can check using the following command: sftp -oPort=11422 xxx@yyyy The following error message is displayed: debug2: bits set: 516/1024 bad sigbloblen 48 != SIGBLOB_LEN Couldn't read packet: Connection reset by peer
Local fix
RTC - 580865
Problem summary
USERS AFFECTED: ALL PROBLEM DESCRIPTION: After upgrading IBM Sterling B2B Integrator to V5.2.6.3_9 the SFTP client receives "Error bad sigbloblen 48 != SIGBLOB_LEN" when connecting to the SFTP Server adapter. PLATFORMS AFFECTED: ALL
Problem conclusion
RESOLUTION SUMMARY: A code fix is provided. DELIVERED IN: 5020603_10
Temporary fix
Comments
APAR Information
APAR number
IT28585
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
526
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-04-03
Closed date
2019-05-13
Last modified date
2019-05-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.6","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
17 May 2019