Troubleshooting
Problem
In an environment of WebSphere Integration Developer (WID) V7.0.0.4 Fixpack or V7.0.0.4 Interim Fix 001 with non-English language installed and shell-shares with Rational Application Developer (RAD) V7.5.5.4, when user upgrades to WID V7.0.0.5 Fixpack, an error is emitted during the upgrade from Installation Manager.
Symptom
The following error is emitted during the upgrade from Installation Manager:
"Error during "complete" phase:
CRIMA1082E: The bundle "com.ibm.ws.ast.wsfp.annotations.processor.nl1_1.1.4.v201110131409" cannot be installed in this Eclipse configuration because it is not equivalent to the bundle "com.ibm.ws.ast.wsfp.annotations.processor.nl1_1.0.103.v20100710_0411" that is already installed."
User will still have WID V7.0.0.4 after the failed upgrade.
There are 2 workarounds
1) Upgrade from RAD V7.5.5.4 to RAD V7.5.5.5 first, then upgrade from WID V7.0.0.4 to WID V7.0.0.5, or
2) Upgrade to both RAD V7.5.5.5 and WID V7.0.0.5 simultaneously.
Cause
This is caused by a problem with how the above bundle is being installed by RAD V7.5.5.4.
Resolving The Problem
Users can either upgrade from RAD V7.5.5.4 to RAD V7.5.5.5 first, then apply the WID V7.0.0.5 upgrade, or upgrade to both RAD V7.5.5.5 and WID V7.0.0.5 simultaneously.
Was this topic helpful?
Document Information
Modified date:
15 June 2018
UID
swg21597047