A fix is available
APAR status
Closed as program error.
Error description
DataPower may experience the below errors upon startup: admin-state enabled host "example.ibm.com" credentials "xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx" exit
Local fix
Remove this from the startup config and reload the device: %if% available "" admin-state enabled host "example.ibm.com" credentials "xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx"
Problem summary
A deprecated object might have persisted and attempted to be configured. Since the deprecation removed the cli command the generated cli is invalid.
Problem conclusion
Prevent the deprecated object from automatically configuring on startup. Fix is available in 2018.4.1.1 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT26010
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
770
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-08-19
Closed date
2018-11-29
Last modified date
2018-12-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
0
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R770 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"770"}]
Document Information
Modified date: