APAR status
Closed as program error.
Error description
If an exception is thrown during the initialization of a connector then the partially constructed connector object is leaked. An example of this is if an exception is thrown when creating an MQTT Output Connector then the Resource Statistics publisher will leak two MQTTOutputConnector Java objects every time it attempts to publish statistics which can lead to Java heap memory exhaustion.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM Integration Bus v10 and IBM App Connect Enterprise v11. Platforms affected: z/OS, MultiPlatform **************************************************************** PROBLEM DESCRIPTION: Memory may be leaked if a Common Connector Framework Connector throws an exception before it's initialization is complete. A known example occurs when the MQTT Connector is used internally for resource publication but the MQTT connection details are not correctly configured.
Problem conclusion
Memory is no longer leaked when a Connector throws an exception before it is fully initialized. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v10.0 10.0.0.14 v11.0 11.0.0.2 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT25886
Reported component name
INTEGRATION BUS
Reported component ID
5724J0540
Reported release
A00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-08-02
Closed date
2018-09-19
Last modified date
2018-09-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INTEGRATION BUS
Fixed component ID
5724J0540
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
19 September 2018