A fix is available
APAR status
Closed as program error.
Error description
If there are no catalogs the register configuration phase is failing and we see stack trace as below in the datapowerlog: Thu Jun 28 2018 20:29:22 [0x80e0084c][apic-gw-service][debug] apic-gw-service(default): tid(322): lib:management:apim:APIMManager: Configure Registration of APIM instance with Gateway Director. Thu Jun 28 2018 20:29:22 [0x88e000c9][apic-gw-service][error] apic-gw-service(default): tid(322): Incoming object is missing property: 0 Thu Jun 28 2018 20:29:22 [0x80e0084c][apic-gw-service][error] apic-gw-service(default): tid(322): utils:validation: Received malformed register configuration data. Missing or malformed property: 0
Local fix
To workaround the problem add a catalog before bringing up a gateway peering
Problem summary
If there are no catalogs, the register configuration phase is failing and we see errors in datapower log.
Problem conclusion
Fix is available in 7.7.1.2 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT25605
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
770
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-07-06
Closed date
2018-10-12
Last modified date
2018-10-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R770 PSY
UP