Fixes are available
APAR status
Closed as program error.
Error description
The user observed that IBM DataPower Gateways XML Management (SOMA) response of "view-certificate-details" action does not comply to its schema (xml-mgmt-ops.xsd). In particular, the "CryptoCertificate" element has to be nested inside of a "view-certificate-details" element which is missing. Due to this mistake it is impossible to use tools like jax-ws to generate code; the generated code cannot parse the provided reply (certificate details). Erroneous response structure: <env:Envelope xmlns:env="http://schemas.xmlsoap.org/soap/envelope/"> <env:Body> <dp:response xmlns:dp="http://www.datapower.com/schemas/management"> <dp:timestamp>2018-01-29T16:09:52+01:00</dp:timestamp> <CryptoCertificate> ... Expected schema compliant response structure: <env:Envelope xmlns:env="http://schemas.xmlsoap.org/soap/envelope/"> <env:Body> <dp:response xmlns:dp="http://www.datapower.com/schemas/management"> <dp:timestamp>2018-01-29T16:09:52+01:00</dp:timestamp> <dp:view-certificate-details> <CryptoCertificate> ...
Local fix
Route all SOMA traffic through a MPGW that applies a transformation to fix the response to adhere to the schema.
Problem summary
SOMA respose for view-certificate-details does not respond with a body that can be correctly validated by the xml-mgmt-ops.xsd schema.
Problem conclusion
Fix is available in 7.5.2.14, 7.6.0.7 and 7.7.1.0 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT24315
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
752
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-03-08
Closed date
2018-05-17
Last modified date
2018-05-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
0
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R770 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"752","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]