Direct links to fixes
APAR status
Closed as program error.
Error description
During system maintenance and after a successful OS upgrade, node 1 is not available but node 2 restarts. It hangs at step "Waiting for ServicesController node1", while the previous steps ("Pre Register node1", "Starting IBM Sterling B2B Integrator Server node1", "Waiting for IBM Sterling B2B Integrator JNDI node1", "Initializing Security node1", "Waiting for IBM Sterling B2B Integrator Server node1") are successfully executed.
Local fix
RTC NO: 552559 1). Check the servicesctl.log file and look at the last line in the log. It will give the name of the Adapter that is failing to start. 2). Disable the adapter with the following command: From /si/install/bin ./db_exec.sh "update service_instance set active_status=0 where service_name = '<ADAPTER_NAME>' " sample: ./db_exec.sh "update service_instance set active_status=0 where service_name = 'SFTP_SERVER_ADAPTER' " Try starting the application with ./run.sh Repeat these steps until SI is able to start again. 3). Then enable the Adapters that you disabled. You can do this from the user interface or by command line From the install directory (one level aboive /bin) /si/install/ bin/opscmd.sh -nnode1 -cSTARTADAPTER -pid=<ADAPTER_NAME> sample: bin/opscmd.sh -nnode1 -cSTARTADAPTER -pid=SFTP_SERVER_ADAPTER
Problem summary
Users Affected: All Problem Description: During system maintenance and after a successful upgrade of the OS, node 1 is not available but node 2 restarts. Deadlock can occur if XpathBPLauncherEventListener is configured for event listner in a cluster. Platforms Affected: All
Problem conclusion
Resolution Summary: A code fix is provided. Delivered In: 5020601_10 5020602_6 5020603_6
Temporary fix
Comments
APAR Information
APAR number
IT23748
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
526
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-01-16
Closed date
2018-04-25
Last modified date
2018-07-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.6","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date: