Error description
After upgrading to V5.2.6.3_3, IBM Sterling B2B Integrator does not start on Solaris. The ops.log contains an entry "Cannot create JVM, unknown option -Xgcpolicy:gencon".
Local fix
RTC NO: 557780 ONLY ON SOLARIS: * Edit the file tmp.sh_platform_ifcresources_ext.in in the <si-install>/bin directory * replace the line (10) JAVA_OPS="${JAVABIN} ${JAVA_FLAGS} -Xms128m -Xmx1024m -Xgcpolicy:gencon " with JAVA_OPS="${JAVABIN} ${JAVA_FLAGS} -Xms128m -Xmx1024m" * stop SI * run setufiles.sh * start SI
Problem summary
Users Affected: All Problem Description: OPS is not starting on Solaris system and HPUX. Found In: All build above 5020603_2 using HP-UX and Solaris machines. Platforms Affected: All
Problem conclusion
Resolution Summary: A code fix is provided. Modified the property tmp.sh_platform_ifcresources_ext.in to remove the GC policy settings. Delivered In: 5020603_5
Temporary fix
Comments
APAR Information
APAR number
IT23579
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
526
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-12-27
Closed date
2018-02-23
Last modified date
2018-03-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.6","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
06 March 2018