Error description
FIFO processing needs to fail over to another node when a node with a running JMS 1.1 Async Receive Adapter is stopped.
Local fix
No workaround
Problem summary
USERS AFFECTED: ALL PROBLEM DESCRIPTION: FIFO processing needs the ability to fail over to another node when a node with a running JMS 1.1 Async Receive Adapter is stopped. PLATFORMS AFFECTED: ALL
Problem conclusion
RESOLUTION SUMMARY: Made code changes to address this issue. As part of this fix, we have introduced two new properties in jms11.properties file as below :- ##PROPERTY_START ##PROPERTY_NAME : useRetryForFIFO ##PROPERTY_TYPE : boolean ##VALID VALUES : true/false ##DEFAULT VALUE : false ##PROPERTY_DESCRIPTION ##This property governs if the JMS 1.1 Async Receive Adapter should attempt for a connection rety or not when the adapter is pinned to more than one node in the cluster and configured in FIFO mode. ##This property is helfpul in achieving fail over capability of the JMS 1.1 Async Receive Adapter. useRetryForFIFO=false ##PROPERTY_START ##PROPERTY_NAME : theadSleepIntervalForRetry ##PROPERTY_TYPE : time in msec ##VALID VALUES : Any valid integer value ##DEFAULT VALUE : 5000 msec (=5s) ##PROPERTY_DESCRIPTION ##This property governs the duration in milliseconds the thread has to sleep when before starting the JMS 1.1 Async Receive Adapter since the last failed attempt to start this adatper. ##This property is helfpul in achieving fail over capability of the JMS 1.1 Async Receive Adapter. theadSleepIntervalForRetry=5000 DELIVERED IN: 5020603_3
Temporary fix
Comments
APAR Information
APAR number
IT22696
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
526
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-10-06
Closed date
2017-11-06
Last modified date
2017-11-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
R526 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.6","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
07 November 2017