APAR status
Closed as program error.
Error description
WSMQ services do not error out even after exceeding the default 3 minutes time interval.
Local fix
RTC NO: 542894
Problem summary
User Affeted: All PROBLEM DESCRIPTION: Session timeout does not honour 3 minutes time interval in WSMQ services. PLATFORM AFFECTED: clump_asset
Problem conclusion
RESOULTION SUMMARY: A code fix is provided. DELIVERED IN: 5020500_18 5020601_10 5020602_6 5020603_6
Temporary fix
Comments
APAR Information
APAR number
IT22458
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
525
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-09-20
Closed date
2018-01-15
Last modified date
2018-07-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"IBM Sterling B2B Integrator"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.5","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date: