Fixes are available
APAR status
Closed as program error.
Error description
The user observed an unexpected JSON Schema Validation failure for a very big decimal value with 20 digits. The logged error message looks like below: "Processing of 'local:///my.jsv' stopped: [FOAR0002] A numeric operation resulted in overflow."
Local fix
Use scientific notation or remove digits to fit decimal precision of 18 digits for JSON decimal number.
Problem summary
Affected is use of JSON Schema Validation. Validation fails for a very big decimal value with more than 18 digits with "[FOAR0002] A numeric operation resulted in overflow." error.
Problem conclusion
Now the correct error "[FOCA0006] String to be cast to decimal has too many digits of precision." gets logged. Fix is available in 7.1.0.18, 7.2.0.15, 7.5.0.9, 7.5.1.8, 7.5.2.8 and 7.6.0.0 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT19052
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
750
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-02-01
Closed date
2017-07-27
Last modified date
2017-08-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R710 PSY
UP
R720 PSY
UP
R750 PSY
UP
R751 PSY
UP
R752 PSY
UP
R760 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"750","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: