Fixes are available
APAR status
Closed as program error.
Error description
A RMI Status request for FirmwareVersion2 returns the serial number as a JSON Number in certain cases, but it needs to be formatted as a JSON String. This happens when the serial number is all numeric digits.
Local fix
Problem summary
Fix RMI support for FirmwareVersion2 serial number as JSON String
Problem conclusion
RMI logic to present strings as JSON strings even if their values are numeric. Fix is available in 7.5.0.6, 7.5.1.5 and 7.5.2.3 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT18928
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-01-20
Closed date
2017-03-17
Last modified date
2017-03-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
0
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R752 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]