Fixes are available
APAR status
Closed as program error.
Error description
The backup of a Microsoft Hyper-V guest might fail with following error: ANS0361I DIAG: vmHypervBackup::ProcessExtent(): Read failed with rc=1117 ANS0361I DIAG: vmHypervBackup::ProcessExtent(): Read failed with rc=122 ANS4169E A write failure occurred on the local disk proxy used to temporarily store the virtual machine virtual disk information. The write failure can be caused by the lack of available disk space on the drive used to store this information. The VMBACKDIR option can be used to assign a different disk location for this purpose. Check the drive being used and ensure that there is enough space available for this operation. [...] ANS1228E Sending of object 'VMguest' failed. The failure is caused by the VHDX size of the Hyper-V guest not being a multiple of 16 KB (16384 bytes). IBM Spectrum Protect Versions Affected: IBM spectrum Protect for Virtual Environments - Data Protection for Microsoft Hyper-V 7.1.6 IBM spectrum Protect for Virtual Environments - Data Protection for Microsoft Hyper-V 8.1 | MDVPARTL 7.1.6.0-TIV_5698ISMCL | IT11599 Customer/L2 Diagnostics: Verify the VHDX size using PowerShell Cmdlet: Get-VHD 'diskname' Where diskname is the fully qualified path to the .vhdx Look for the 'Size' field. If this value is not a multiple of 16384 bytes, this APAR applies. Initial Impact: Medium Additional Keywords: TSM, Tivoli, Storage, Manager, Hyperv, MS, VM, IT11599
Local fix
Resize the VHDX file to a multiple of 16384 bytes using Microsoft PowerShell Cmdlet: Resize-VHD -path 'diskname.vhdx' -SizeBytes <Size in bytes>
Problem summary
**************************************************************** * USERS AFFECTED: * * Data Protection for Microsoft Hyper-V versions 7.1.3, 7.1.4, * * 7.1.6 and 8.1.0 running on all Microsoft Windows x64 * * platforms * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION * **************************************************************** * RECOMMENDATION: * * This issue is projected to be fixed in the Backup-Archive * * Client version 7.1.6.5, 7.1.8, 8.1.0.2, 8.1.2 on all * * Microsoft Windows x64 platforms * * * * Note 1: The Backup-Archive Client is a part of the Data * * Protection for Microsoft Hyper-V. In Data Protection for * * Microsoft Hyper-V environments, the Backup-Archive Client is * * also known as the data mover. * * Note 2: This is subject to change at the discretion of IBM. * ****************************************************************
Problem conclusion
Algorithm that calculates amount of data to sent during backup was updated to correctly handle cases when VHDX size is not multiply of 16834 bytes.
Temporary fix
Comments
APAR Information
APAR number
IT18678
Reported component name
TSM VE DP MS HY
Reported component ID
5725TVEHV
Reported release
71W
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-01-06
Closed date
2017-03-30
Last modified date
2017-03-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DSMC
Fix information
Fixed component name
TSM CLIENT
Fixed component ID
5698ISMCL
Applicable component levels
R71W PSY
UP
R81W PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"71W","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
11 January 2022