APAR status
Closed as program error.
Error description
At boot time you see the error during the secure boot phase insmod: can't insert '/lib/modules/2.6.32-431.29.2.dp_800.15.x86_64/aesni-intel.ko': unknown symbol in module, or unknown parameter. There are no adverse affects from this message.
Local fix
Upgrade to firmware version 9.0.1
Problem summary
**************************************************************** USERS AFFECTED: This issue affects users of the MQ v8 Appliance, who are reviewing the console output after booting the appliance. Platforms affected: MultiPlatform **************************************************************** PROBLEM DESCRIPTION: An omission in the configuration of the secure boot phase of the MQ appliance resulted in some modules being loaded out of sequence. This had no adverse affect, as the correct set of module was loaded during the boot process, but the error described above was reported as a result.
Problem conclusion
The MQ Appliance secure boot phase has been updated to prevent these modules being loaded out of sequence. Some customers may still observe this message during the initial cleartext boot phase. The same issue within the cleartext boot phase is addressed by the MQ Appliance v 9.0.1 or later firmware. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v8.0 8.0.0.7 The latest available maintenance can be obtained from 'WebSphere MQ Recommended Fixes' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037 If the maintenance level is not yet available information on its planned availability can be found in 'WebSphere MQ Planned Maintenance Release Dates' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT18630
Reported component name
IBM MQ APPL M20
Reported component ID
5725S1400
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-01-03
Closed date
2017-07-07
Last modified date
2017-07-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
IBM MQ APPL M20
Fixed component ID
5725S1400
Applicable component levels
R800 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS5K6E","label":"IBM MQ Appliance"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]
Document Information
Modified date: