Error description
The cicsas process fails to load the CICS trigger monitor because of a symbol lookup error such as "amqltmc0: undefined symbol: xcsCheckConsistency".
Local fix
Problem summary
**************************************************************** USERS AFFECTED: All users of the CICS trigger monitor (amqltcm0 or amqltmcc) on Linux. Platforms affected: Linux on x86-64 **************************************************************** PROBLEM DESCRIPTION: The CICS trigger monitor on Linux was not linked with the necessary shared libraries for it to run, so an attempt to use the CICS trigger monitor failed as it could not be loaded.
Problem conclusion
The CICS trigger monitor on Linux was changed to link with the necessary shared libraries for it to run. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v8.0 8.0.0.6 v9.0 CD 9.0.2 v9.0 LTS 9.0.0.1 The latest available maintenance can be obtained from 'WebSphere MQ Recommended Fixes' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037 If the maintenance level is not yet available information on its planned availability can be found in 'WebSphere MQ Planned Maintenance Release Dates' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT18489
Reported component name
WMQ BASE MULTIP
Reported component ID
5724H7251
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-12-20
Closed date
2017-01-25
Last modified date
2017-03-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WMQ BASE MULTIP
Fixed component ID
5724H7251
Applicable component levels
R800 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSYHRD","label":"IBM MQ"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
10 March 2017