APAR status
Closed as program error.
Error description
After upgrading to MQ 8.0.0.5 or 8.0.0.6 fix pack MQRC_NOT_AUTHORIZED error events are generated for the user account under which the connecting application runs. Additionally, on Windows platform AMQ8075 (Authorization failed because the SID for entity '<insert one>' cannot be obtained) errors are reported in the queue manager logs.
Local fix
N/A
Problem summary
**************************************************************** USERS AFFECTED: Users using applications that pass MQCSP user for authenticating a queue manager connection. Platforms affected: MultiPlatform **************************************************************** PROBLEM DESCRIPTION: This change was introduced in fix pack 8.0.0.5 by APAR IT12825. A logic error within this change caused the authorization error to be incorrectly reported for valid credentials, however the connection attempt would still succeed if the supplied credentials were valid.
Problem conclusion
MQ code is updated such that the authentication/validation is performed only when appropriate. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v8.0 8.0.0.7 The latest available maintenance can be obtained from 'WebSphere MQ Recommended Fixes' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037 If the maintenance level is not yet available information on its planned availability can be found in 'WebSphere MQ Planned Maintenance Release Dates' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT17691
Reported component name
WMQ BASE MULTIP
Reported component ID
5724H7251
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-10-27
Closed date
2017-05-30
Last modified date
2017-05-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WMQ BASE MULTIP
Fixed component ID
5724H7251
Applicable component levels
R800 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSYHRD","label":"IBM MQ"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
30 May 2017