Fixes are available
Fix packs for DataPower Service Gateway version 7.0
Fix packs for DataPower B2B Appliance version 7.0
Fix packs for DataPower Integration Appliance version 7.0
Fix packs for DataPower Gateway version 7.1
Fix packs for DataPower Gateway version 7.2
Fix packs for DataPower Gateway version 7.5
Fix packs for DataPower Gateway version 7.5.1
APAR status
Closed as program error.
Error description
The user observed DataPower to restart unexpectedly on trying to compile a WSDL that contains an invalid non-URL attribute text for <soap:address location="..."/>, e.g. <soap:address location="REPLACE_WITH_ACTUAL_URL"/>. For further reading, compare also "DataPower firmware V6 and later does not allow WSDLs with a non-digit port value for soap:address location URLs" at http://www.ibm.com/support/docview.wss?uid=swg21668433
Local fix
Ensure to define a valid URL, e.g. <soap:address location="http://myserver:4321/service/hello" / >
Problem summary
Affected is the compilation of a WSDL. If a WSDL contains an invalid non-URL soap:address attribute, the appliance might restart.
Problem conclusion
The fix is available in 7.0.0.14, 7.1.0.11, 7.2.0.8, 7.5.0.2 and 7.5.1.2 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT14807
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-04-15
Closed date
2016-07-25
Last modified date
2016-09-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
0
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R750 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: