Fixes are available
APAR status
Closed as program error.
Error description
Affected is use of GatewayScript readAsJSON() function for parsing UTF-8 encoded JSON input that is prefixed with a BOM. DataPower will report a parsing error incorrectly.
Local fix
Use readAsBuffer(... buf ...) instead, together with JSON.parse(buf.toString('utf8')).
Problem summary
Affected is use of GatewayScript readAsJSON() function. Parsing valid UTF-8 encoded JSON input that is prefixed with a BOM will report a parsing error incorrectly.
Problem conclusion
Fix is available in 7.0.0.13, 7.1.0.10, 7.2.0.5 and 7.5.0.0 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT14295
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-14
Closed date
2016-03-20
Last modified date
2016-05-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R700 PSY
UP
R710 PSY
UP
R720 PSY
UP
R750 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0.0"}]
Document Information
Modified date:
26 September 2021