Fixes are available
Fix packs for DataPower Service Gateway version 7.0
Fix packs for DataPower B2B Appliance version 7.0
Fix packs for DataPower Integration Appliance version 7.0
Fix packs for DataPower Gateway version 7.1
Fix packs for DataPower Gateway version 7.2
Fix packs for DataPower Gateway version 7.5
Fix packs for DataPower Gateway version 7.5.1
APAR status
Closed as program error.
Error description
The DataPower device may restart due to large number of MQ connections being used for high volume traffic and the mq-qm object goes down resulting in many MQ errors with reason code of 2059.
Local fix
Problem summary
When using MQ backend with connection timeout, the DataPower device may restart due to large number of MQ connections resulting in many MQ errors of 2059 reason code.
Problem conclusion
Fix is available in 7.0.0.14, 7.1.0.11, 7.2.0.8, 7.5.0.2 and 7.5.1.2 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT14267
Reported component name
DTPWR INTGRAPL
Reported component ID
DP905XI52
Reported release
601
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-11
Closed date
2016-05-23
Last modified date
2016-09-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DTPWR INTGRAPL
Fixed component ID
DP905XI52
Applicable component levels
R700 PSY
UP
R710 PSY
UP
R720 PSY
UP
R750 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSHT9H","label":"WebSphere DataPower Integration Appliance XI52"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1"}]
Document Information
Modified date: