A fix is available
APAR status
Closed as program error.
Error description
When configuring a Datapower Secure Gateway Client to integrate with BlueMix applications, the client shows op-state=up and the BlueMix side reports the tunnel is up too. However, when trying to use the configured destination, DataPower shows the following error: 0x8860001f - sgclient (BlueMix_Gateway): An unrecognized op code 2 was received on the Secure Gateway tunnel
Local fix
Problem summary
Affected is use of Bluemix with DataPower Secure Gateway Client. When configuring a Datapower Secure Gateway Client to integrate with BlueMix applications, the client shows op-state=up and the BlueMix side reports the tunnel is up too. However, when trying to use the configured destination, DataPower logs an error.
Problem conclusion
Fix is available in 7.2.0.5 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT14108
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-03
Closed date
2016-03-20
Last modified date
2016-03-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R720 PSY
UP