Fixes are available
Fix packs for DataPower XML Security Gateway version 6.0
Fix packs for DataPower B2B Appliance version 6.0
Fix packs for DataPower Integration Appliance version 6.0
Fix packs for DataPower Low Latency Appliance version 6.0
Fix packs for DataPower Service Gateway version 6.0
Fix packs for DataPower Service Gateway version 6.0.1
Fix packs for DataPower B2B Appliance version 6.0.1
Fix packs for DataPower Integration Appliance version 6.0.1
Fix packs for DataPower Service Gateway version 7.0
Fix packs for DataPower B2B Appliance version 7.0
Fix packs for DataPower Integration Appliance version 7.0
Fix packs for DataPower Gateway version 7.1
Fix packs for DataPower Gateway version 7.2
APAR status
Closed as program error.
Error description
When a large XSLT containing / in the dp:summary section is uploaded onto the DataPower device using Internet Explorer, the WebGUI (internet explorer session) eventually hangs.
Local fix
Example: The issue is caused by the forward slash (/) in the <description> element in the attached XSL file: <dp:summary> <operation>xform</operation> <description> ... var://context/ZlinuxResponse' ... </description> </dp:summary> Removing the forward slashes (/) would be a workaround and can fix the hanging.
Problem summary
Viewing XSLT file that contains forward slash in the dp:summary section might hang on WebGUI using IE.
Problem conclusion
Fix is available in 6.0.0.17, 6.0.1.13, 7.0.0.10, 7.1.0.7 and 7.2.0.2 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT10890
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
601
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-08-24
Closed date
2015-10-19
Last modified date
2015-11-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R600 PSY
UP
R601 PSY
UP
R700 PSY
UP
R710 PSY
UP
R720 PSY
UP
Document Information