Fixes are available
Fix packs for DataPower B2B Appliance version 6.0
Fix packs for DataPower Integration Appliance version 6.0
Fix packs for DataPower B2B Appliance version 6.0.1
Fix packs for DataPower Integration Appliance version 6.0.1
Fix packs for DataPower B2B Appliance version 7.0
Fix packs for DataPower Integration Appliance version 7.0
Fix packs for DataPower Gateway version 7.1
Fix packs for DataPower Gateway version 7.2
APAR status
Closed as program error.
Error description
Deleting the diag-log from the logtemp directory can result in unreleased temporary space growth. To recover from this a reload of the firmware or reboot of the hardware is needed.
Local fix
Do not delete the diag-log.
Problem summary
Affected are all DataPower installations. Deletion of the diag-log file is not done correctly and the file continues to grow using up temporary space. This eventually leads to a restart.
Problem conclusion
Fix is available in 6.0.0.16, 6.0.1.12, 7.0.0.9, 7.1.0.6 and 7.2.0.2. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT09575
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-06-19
Closed date
2015-08-26
Last modified date
2015-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R600 PSY
UP
R601 PSY
UP
R700 PSY
UP
R710 PSY
UP
R720 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: