Fixes are available
Fix packs for DataPower B2B Appliance version 6.0
Fix packs for DataPower Integration Appliance version 6.0
Fix packs for DataPower B2B Appliance version 6.0.1
Fix packs for DataPower Integration Appliance version 6.0.1
Fix packs for DataPower B2B Appliance version 7.0
Fix packs for DataPower Integration Appliance version 7.0
Fix packs for DataPower Gateway version 7.1
Fix packs for DataPower Gateway version 7.2
APAR status
Closed as program error.
Error description
If Log Target with Archive Mode Upload cannot reach its remote target it will continue to Log files to be sent. Currently the Log Target will only mark the oldest file as '.unsent' without cycling through any other files, if any. This may cause, over time a buildup of Log Files associated with this target until the Remote Target is brought back up.
Local fix
Disable Log Targets that cannot reach their configured remote target. No functionality is lost when disabling the object when the remote target is down because the Log Targets cannot upload any data.
Problem summary
Affected is the use of Log Target with archive mode upload. The fix will ensure that even if the upload of the file has failed the file will be renamed to '.unsent'.
Problem conclusion
There can be loss of log data if the remote server is down for an extended period of time. The fix will prevent the ramdisk from becoming full. The fix is available in 6.0.0.16, 6.0.1.12, 7.0.0.9, 7.1.0.6 and 7.2.0.2. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT09552
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-06-18
Closed date
2015-08-25
Last modified date
2015-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
NONE 0
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R720 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]