A fix is available
APAR status
Closed as program error.
Error description
Entering the "test hardware" command on an XG45 appliance might report a problem with DIMM memory.
Local fix
Problem summary
The "test hardware" command correctly distinguishes between memory that is offline due to an error, and memory that is not installed.
Problem conclusion
Fix is available in 7.1.0.1. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT05557
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-11-18
Closed date
2014-11-20
Last modified date
2014-11-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R710 PSY