Fixes are available
Fix packs for DataPower B2B Appliance version 6.0
Fix packs for DataPower Integration Appliance version 6.0
Fix packs for DataPower Service Gateway version 6.0
Fix packs for DataPower Service Gateway version 6.0.1
Fix packs for DataPower B2B Appliance version 6.0.1
Fix packs for DataPower Integration Appliance version 6.0.1
Fix packs for DataPower Service Gateway version 7.0
Fix packs for DataPower B2B Appliance version 7.0
Fix packs for DataPower Integration Appliance version 7.0
APAR status
Closed as program error.
Error description
When using the on demand router, session affinity might not be maintained depending on the order of the cookies in the header sent to DataPower. This produces an error in the log with the following format: Affinity was broken for a request because Server was not found for cloneId '<CloneID>; ABC=abc' Where ABC is an extraneous cookie and <CloneID> is the expected cloneID.
Local fix
Problem summary
For customers using 6.0.0.9, 6.0.1.5 or 7.0.0.2, when using ODR with DataPower, the appliance might fail to parse multiple cookie values properly.
Problem conclusion
Fix is available in 6.0.0.10, 6.0.1.5 and 7.0.0.3. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT03971
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
601
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-08-22
Closed date
2014-11-13
Last modified date
2014-11-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R600 PSY
UP
R601 PSY
UP
R700 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]