A fix is available
APAR status
Closed as program error.
Error description
Environment: Windows ONLY. Upgrade of 6.2.2 FP9 NT Agent to 6.2.3 FP1 NT Agent. Problem Description: When coding new connection parameters the number of protocols coded must match the existing number, or residual values will remain. Also the agent must be unconfigured before the upgrade. See examples that follow to see how the protocols work. Primary Protocols protocol1=IP.SPIPE protocol2=IP.PIPE FTO protocols FTO_protocol1=IP.SPIPE FTO-protocol2-IP.PIPE If only IP.SPIPE is coded in the CMA_CONFIG area of the silent install file, the IP-PIPE value is retained. However, if protocol2 is coded as protocol2=IP.SPIPE and FTO_protocol2=IP.SPIPE then only the IP.SPIPE value is retained. Recreate Instructions: 1. Install 6.2.2 FP9 NT agent and configure as follows: Primary TEEMS Connection protocol1=IP.SPIPE protocol2=IP.PIPE Configure Secondary TEMS Connection: protocol1=IP.SPIPE protocol2=IP.PIPE 2. Upgrade to 6.2.3 FPx where fix is present silently: a. Stop the agent b. Unconfigure the agent c. Add the following to the upgrade silent file [CMA_CONFIG] Protocol1=IP.SPIPE IPSPIPE_Port=3660 IPSPIPE_Host=TEMSHOSTNAME FTO Flag=Y FTO_Protocol1=IP.SPIPE FTO_IPSPIPE_Host=FTOTEMSHOSTNAME 3. If the fix is present only 1 protocol will remain for the NT agent. If the fix is not present, both IP.SPIPE and IP.PIPE protocols will be present. 4. The problem is in the Agent Defaults area. If the defaults are going to be used they should reflect the settings in the silent install file.
Local fix
To work around this problem code the CMA section as follows: [CMA_CONFIG] Protocol1=IP.SPIPE Protocol2=IP.SPIPE IPSPIPE_Port=3660 IPSPIPE_Host=PRIMARYTEMSHOSTNAME FTO Flag=Y FTO_Protocol1=IP.SPIPE FTO_Protocol2=IP.SPIPE FTO_IPSPIPE_Host=SECONDARYTEMSHOSTNAME By making protocol2 match protocol1 only that protocol will be retained.
Problem summary
On Windows, a user provides a [CMA_CONFIG] section in their silent install upgrade response file to change connection properties of the agents being upgraded. The information in the [CMA_CONFIG] section may be processed incorrectly during the upgrade. For example, if two protocols currently exist and only one is desired, the outcome of the configuration can be unpredictable.
Problem conclusion
Code was modified to process the response file during upgrade when an agent is reconfigured and the [CMA_CONFIG] section is present. The fix unconfigures any Primary agent or instances upgraded then configures them using the new protocol information. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.2.3-TIV-ITM-FP0005
Temporary fix
Reconfigure the agent and any instances using the Manage Tivoli Enterprise Monitoring Services tool after the upgrade completes, and configure them with the new protocol information.
Comments
APAR Information
APAR number
IV41655
Reported component name
OMEG DIST INSTA
Reported component ID
5608A41CI
Reported release
623
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-05-07
Closed date
2013-10-31
Last modified date
2014-05-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
OMEG DIST INSTA
Fixed component ID
5608A41CI
Applicable component levels
R623 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"623"}]
Document Information
Modified date: