IBM Support

System.out logs filled with repeated warnings about SCI.Server.Name not specified

Troubleshooting


Problem

Your system.out logs are filled with repeated WARN messages about SCI.Server.Name not specified.

Symptom

App server system logs get filled up with many repetitions of the following warning (format of line may vary, but bold pieces will be consistent)

Error Message

####<Jan 4, 2010 3:14:55 PM EST> <Notice> <Stdout> <xxxapp.na.int.grp> <AppServer> <[ACTIVE]
ExecuteThread: '26' for queue: 'weblogic.kernel.Default (self-tuning)'> <<WLS Kernel>> <> <> <1262636095906> <000000><2010-01-04 15:14:55,906:WARN :[ACTIVE] ExecuteThread:
'26' for queue: 'weblogic.kernel.Default (self- tuning)':
SCI.Server.Name not specified using: AppServer_Prod
[USERX]: YCPSystem>

Resolving The Problem

From the 8.0 System Management Guide, section 2.1.2.1, Server Name

To monitor your application servers, you must give each server a unique name so that System Management can uniquely identify each server. To give a unique name to an application server, add the following command line parameter to the Java command within the server start up script:

-DSCI.Server.Name=<unique name>

Even if multiple server processes are run on the same machine, it is mandatory to give each server process a unique name. Therefore, it might be necessary to create separate start up scripts even when starting multiple instances of the server on the same machine.

[{"Product":{"code":"SS6PEW","label":"IBM Sterling Order Management"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Component":"Not Applicable","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"9.2;9.1;9.0","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]