Error description
itmcmd agent -o instance -f stop bn stops the wrong agent instance when cinfo reports that instance as "process not running". RECREATE INSTRUCTIONS: [root@sysa]# /opt/IBM/ITM/bin/cinfo -r systema bn 167 root 11:11 SY00_sysa ...running systema bn 176 root 11:11 SY02_sysa ...running [root@sysa]# ps -ef | grep ITM | grep bn root 167 1 6 11:11 pts/0 00:00:16 /opt/IBM/ITM/lx8266/bn/bin/kbnagent sysa_SY00_systema root 176 1 3 11:11 pts/0 00:00:12 /opt/IBM/ITM/lx8266/bn/bin/kbnagent sysa_SY02_systema [root@sysa]# kill 176 [root@sysa]# /opt/IBM/ITM/bin/cinfo -r systema bn 167 root 11:11 SY00_sysa ...running systema bn 176 SY02_sysa ...process not running [root@sysa]# /opt/IBM/ITM/bin/itmcmd agent -o SY02_sysa -f stop bn Stopping DataPower Monitoring Agent ... Product DataPower Monitoring Agent was stopped gracefully. Agent stopped... [root@sysa]# /opt/IBM/ITM/bin/cinfo -r systema bn 176 SY02_sysa ...process not running SY00_sysa was stopped instead of SY02_sysa as requested.
Local fix
cinfo -R before attempting to stop an agent instance
Problem summary
Command "itmcmd agent -o <INSTANCE> stop bn" can stop the wrong instance. For example, when multiple instances (inst1, inst2) of the bn agent are started and inst2 terminates, the "itmcmd agent -o inst2 stop bn" may stop inst1 instead.
Problem conclusion
The code was fixed to only stop the instance specified. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.2.2-TIV-ITM-FP0008 | fix pack | 6.2.3-TIV-ITM-FP0002
Temporary fix
Comments
APAR Information
APAR number
IV09745
Reported component name
OMEG DIST INSTA
Reported component ID
5608A41CI
Reported release
622
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-10-25
Closed date
2012-01-09
Last modified date
2012-05-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
OMEG DIST INSTA
Fixed component ID
5608A41CI
Applicable component levels
R622 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"622","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
14 November 2022