APAR status
Closed as program error.
Error description
Error Message: N/A . Stack Trace: N/A .
Local fix
Identify the method with the problematic sequence. Use -Xjit:exclude to exclude JIT compilation of the method.
Problem summary
The problem is caused when the JIT compiler prematurely clobbering a value in register with the SR/SRL sequence. The failure will show up on Linux on Z and zOS platforms only.
Problem conclusion
This defect will be fixed in: 6.0.1 SR1 7.0.0 SR1 . The JVM has been updated to prevent the problem from occurring. . To obtain the fix: Install build 20110921 or later
Temporary fix
Comments
APAR Information
APAR number
IV07581
Reported component name
JIT
Reported component ID
620700124
Reported release
260
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-09-13
Closed date
2011-09-20
Last modified date
2012-05-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
JIT
Fixed component ID
620700124
Applicable component levels
R260 PSY
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSC9HBA","label":"Just In Time (JIT) Compiler"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"260","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
28 May 2012