APAR status
Closed as program error.
Error description
A message-driven bean application, using a WebSphere Application Server Listener Port and a message selector, fails to receive any messages even though there are messages on the queue monitored by the Listener Port that match the selector.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: This issue affects three categories of user: Category 1: ----------- Users of: - The WebSphere Application Server V8.5 WebSphere MQ messaging provider who have message-driven bean applications that: - Have been deployed to use either Listener Ports, or Activation Specifications, that connect to WebSphere MQ using WebSphere MQ messaging provider migration mode. - And use message selectors. Category 2: ----------- Users of: - The WebSphere MQ V7.1 Resource Adapter - The WebSphere MQ V7.5 Resource Adapter - The WebSphere MQ V8.0 Resource Adapter who have message-driven bean applications that: - Have been deployed to use an Activation Specification which connects to WebSphere MQ using WebSphere MQ messaging provider migration mode. - And use message selectors. Category 3: ----------- Users of: - The WebSphere MQ V7.1 classes for JMS - The WebSphere MQ V7.5 classes for JMS - The WebSphere MQ V8.0 classes for JMS who have applications that: - Connect to WebSphere MQ using WebSphere MQ messaging provider migration mode. - And use MessageListeners that have been created with a message selector. Platforms affected: MultiPlatform **************************************************************** PROBLEM DESCRIPTION: The WebSphere MQ classes for JMS maintain an internal flag for every JMS application that uses either: - JMS MessageListeners - Activation Specifications - WebSphere Application Server Listener Ports and connects to WebSphere MQ using WebSphere MQ messaging provider migration mode. The flag represents the state of the application. It is set to true when the application is in a position to receive messages, and false if the application has been stopped and is unable to process messages at the current time. When message selectors are being used, then the WebSphere MQ classes for JMS will check each message that arrives on the JMS Destination being monitored by the MessageListener, Activation Specification or Listener Port to see if it matches the selector specified by an application. If it does, then the WebSphere MQ classes for JMS look at the internal flag for the application, to check that it is in a position to receive the message - if the application is able to process the message, then it is removed from the Destination and delivered to the application for processing. If the internal flag is set to false, however, then the application is not able to process the message at the current time. In this situation, the message is left on the Destination. Due to an error in the WebSphere MQ classes for JMS, the internal flag was always set to false for applications that used message selectors. As a result, the WebSphere MQ classes for JMS would never attempt to deliver messages that matched a message selector to the application using that selector.
Problem conclusion
The WebSphere MQ classes for JMS have been updated to ensure that the internal flag representing the state of applications using message selectors is set to true when the application is in a position to receive messages, and false when the application has been stopped. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v7.1 7.1.0.8 v7.5 7.5.0.6 v8.0 8.0.0.3 The latest available maintenance can be obtained from 'WebSphere MQ Recommended Fixes' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037 If the maintenance level is not yet available information on its planned availability can be found in 'WebSphere MQ Planned Maintenance Release Dates' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IV72011
Reported component name
WMQ AIX V7
Reported component ID
5724H7221
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-04-09
Closed date
2015-05-25
Last modified date
2015-11-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WMQ AIX V7
Fixed component ID
5724H7221
Applicable component levels
R710 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFKSJ","label":"WebSphere MQ"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1"}]
Document Information
Modified date: