Error description
Master reset event not clearing situations opened from previously active hub monitoring server in a hot-standby scenario. Recreate: - Customer configured hot standby for HTEMS - Have a sampled situation that is TRUE. Event is received correctly in OMNIbus. - Perform a failover of the HTEMS. - The newly active HTEMS sends a master reset event to OMNIbus - Events previously opened from the original HTEMS should be closed, but they still remain open.
Local fix
Problem summary
Master reset event sent not clearing situations in ONMIbus opened from previously active hub monitoring server in a hot-standby scenario. In order for this APAR to be properly implemented in your environment, the Event Synchronization from the IBM Tivoli Monitoring (tec) 6.3.0 FP7 install image needs to be installed. See the "Install Actions" section of the APAR conclusion for more details
Problem conclusion
The code was changed so the master reset event triggers the closing of the situations from the previously active hub. Install Actions: ---------------- This fix for this APAR requires the Event Sychronization from the IBM Tivoli Monitoring (tec) 6.3.0 FP7 install image to be installed. Once installed the updated itm_event.rules file should be copied from the <Event Synch Install Directory>/omnibus directory to each Netcool/OMNIbus ObjectServer, to the $OMNIHOME/probes/<archictecture> directory. If you have previously customized the itm_event.rules file, determine what customizations were made to the file and merge your customized rules for IBM Tivoli Monitoring events into the itm_event.rules provided with this update. The EIF probe should then be restarted to pick up the changes. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.3.0-TIV-ITM-FP0007
Temporary fix
Comments
APAR Information
APAR number
IV70874
Reported component name
TEMS
Reported component ID
5724C04MS
Reported release
623
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-03-12
Closed date
2016-03-23
Last modified date
2017-01-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEMS
Fixed component ID
5724C04MS
Applicable component levels
R630 PSY
UP
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCTLMP","label":"ITM Tivoli Enterprise Mgmt Server V6"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"623","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
06 January 2017