Fixes are available
APAR status
Closed as program error.
Error description
ENVIRONMENT: ITM 6.2.1 OMXE for Msg 7.0 Platform AIX ------- PROBLEM DESCRIPTION : Using the tacmd editUser command fails yet the Gui succeeds Reproduced in L2 & L3 lab User command and error displayed "CLI is not currently able to handle the permission properties for users when there is a different REALM / Namespace on TEPS..like it is for MQ agents. eg : /home/users/itmadmin/tim > tacmd edituser -i itmuser -f -u itmadmin -w '<pwd>' -p "Permissions=Configure.View=F" KUICEU001I Validating user credentials... KUICEU002I The user itmadmin has been successfully edited on the TEPS located at http://localhost:1920. Cmd has succesfully exited, but the change has not been made. /home/users/itmadmin/tim > tacmd viewuser -i itmuser -p ... ... Configure : View=T, Modify=T Correct value for "View" above should be "View=F". Confirmed by TACMD L3 as defect, requires APAR.
Local fix
The GUI interface will succeed.
Problem summary
The tacmd edituser CLI is not currently able to handle the permission properties for users when there is a different Realm / Namespace on portal server like it is for MQ agents. The CLI edituser reports success but the change has not actually been made.
Problem conclusion
The problem has been fixed with proper checking of the defined user permissions belonging to all the realms (including the non-standard ones as permission related to MQ agent) The fix for this APAR is included in the following maintenance vehicle: | interim fix | 6.2.1-TIV-ITM-FP0003
Temporary fix
Edit the permissions via the portal client rather than the CLI.
Comments
APAR Information
APAR number
IZ68708
Reported component name
TEMS
Reported component ID
5724C04MS
Reported release
621
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-01-27
Closed date
2010-04-27
Last modified date
2010-07-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEMS
Fixed component ID
5724C04MS
Applicable component levels
R621 PSY
UP