APAR status
Closed as program error.
Error description
Environment: ITM 621 Unix/Lunix Problem Description: The command reference for itmcmd says the -c command option in 'itmcmd agent -c start xx' indicates that the configuration file used on agent startup should not be updated or regenerated. This command option appears to be ignored. Detailed Recreation Procedure: a) Install an agent (ux, ul, lz, cq, or whatever) b) itmcmd config -A xx c) ls -l CANDLEHOME/config/xx.config d) itmcmd agent -c start xx e) ls -l CANDLEHOME/config/xx.config The last step will show the time stamp of xx.config has changed after the agent was started.
Local fix
No current local fix or Workaround itcmd config -c will update and regenerate the config file
Problem summary
In 6.21, the option -c does not work. pc.config file is regenerated even though the option is specified.
Problem conclusion
There are two causes for the issue: 1. In the installer codes, the option is overwritten by the default value which is without -c. 2. For Unix/Linux OS agent, the codes used to start watchdog regenerate the config file The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.2.1-TIV-ITM-FP0001 | fix pack | 6.2.2-TIV-ITM-FP0002
Temporary fix
Comments
APAR Information
APAR number
IZ59893
Reported component name
OMEG DIST INSTA
Reported component ID
5608A41CI
Reported release
621
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-09-03
Closed date
2009-10-19
Last modified date
2010-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
OMEG DIST INSTA
Fixed component ID
5608A41CI
Applicable component levels
R621 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"621","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]