Error description
Problem Description: When the customer specify the "NewLogBasedOn=mtime" variable in the tecad_logfile.conf, "chmod nnn file" causes to fire the event. Failing TEC Component(s): adapter Customer/Recreate Environment: HP-UX 11 Database: N/A TME Framework: 4.1.1 + TMF-0070 Install Method: Upgrade TEC Server: TEC 3.9.0+FP05 Tec Gateway: TEC 3.9.0+FP05 Tec UI Server: TEC 3.9.0+FP05 Websphere server: N/A Tec Console: N/A Endpoints: 41138 Adapter: TEC 3.9.0+FP05 TMR/TEC same machine: YES Affected Locale(s): N/A Collected Information : none (Placed in l2l3 folder - /tivoli/tec/l2l3/APARs/) Last Known Good Level: N/A L3 Acknowledged: Yes/No (LB) Recreate Steps/Correct information: (Defect) I tested this behavior on my AIX environment. I performed the following operation. 1. Edit the ACP profile 2. Specify the "ctime" to the "NewLogBasedOn" parameter and save it. 3. Distribute the profile to the endpoint. 4. perform the following operation to check - touch file - chmod NNN file - chgrp group file Continue from step-1. changing the "NewLogBasedOn" parameter to "mtime" and "cmtime". The result is as follows. The event was sent on all of cases. ------------------------------------------------------ NewLogBasedOn | touch file | chmod | chgrp | ------------------------------------------------------ mtime | sent event | sent event | sent event | ------------------------------------------------------ Local fix: none
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of TEC EEIF adapters on Unix **************************************************************** * PROBLEM DESCRIPTION: When an adapter config file contains the * following keyword and value: NewLogBasedOn=mtime, the adapter * will still treat the log as new when the size does not change, * but the ctime does change. **************************************************************** * RECOMMENDATION: Apply maintenance vehicle listed below **************************************************************** This functionality was not implemented on Unix- on creation time was tracked, etc.
Problem conclusion
ctime was the only attribute preserved in the structures that tracked each logsource. Added mtime for Unix and associated logic to update, check, etc. Now the Unix adapters behave as the Win adapters in that mtime, ctime and cmtime are all valid checked values as per the existing doc on these values. The fix for this APAR is contained in the following maintenance packages: | LA Fix | 3.9.0.8-TIV-TEC-LA0091 Note: Search IBM Technical Support web site for maintenance package availability.
Temporary fix
N/A
Comments
APAR Information
APAR number
IZ24175
Reported component name
TIVOLI ENT.CONS
Reported component ID
5698TEC00
Reported release
390
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-06-11
Closed date
2008-07-09
Last modified date
2008-07-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TIVOLI ENT.CONS
Fixed component ID
5698TEC00
Applicable component levels
R390 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGMKC","label":"Tivoli Enterprise Console"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"390","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
09 July 2008