Readmes are available
IBM Tivoli 4.0.0-TIV-SSM-FP0010
IBM Tivoli 4.0.0-TIV-SSM-FP0011
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 12 README 4.0.0-TIV-SSM-FP0012
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 13 README 4.0.0-TIV-SSM-FP0013
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 14 README 4.0.0-TIV-SSM-FP0014
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.0.14-TIV-SSM-IF0001
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 2 README 4.0.0.14-TIV-SSM-IF0002
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 3 README 4.0.0.14-TIV-SSM-IF0003
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 4 README 4.0.0.14-TIV-SSM-IF0004
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 5 README 4.0.0.14-TIV-SSM-IF0005
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 6 README 4.0.0.14-TIV-SSM-IF0006
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 7 README 4.0.0.14-TIV-SSM-IF0007
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 8 README 4.0.0.14-TIV-SSM-IF0008
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.0.15-TIV-SSM-IF0001
APAR status
Closed as program error.
Error description
Setting 'timer dayofweek=undefined' in a config script sets the day to sunday instead of undefined The result of an incompatibility between the timer MIB design and the configurator library which handles the config language. Steps to replicate : SSM 4.0.0 build 906. - MIB Explorer. timer > timeControlTable - create row (had Status field "notReady", DayOfWeek and Month are both undefined - login to TextConsole and issue "config save" - restart SSM service - DayOfWeek changes to sunday, Month to january.
Local fix
Switch to the crontab MIB which have equivalent features. http://publib.boulder.ibm.com/infocenter/tivihelp/v15r1/topic/co m.ibm.netcool_ssm.doc/rg/topic/crontab_intro_g.html
Problem summary
Setting timreControlDayOfWeek or timerControlMonth to "undefined" is a configuration script sets the value to Sunday or January respectively instead of undefined.
Problem conclusion
The timer subagent has been fixed to interpret the "undefined" value correctly. It now sets the timerControlDayOfweek or timerControlMonth values to "undefined" or -1. The fix for this APAR is contained in the following maintenance packages: | fix pack | 4.0.0-TIV-SSM-FP0004
Temporary fix
Comments
APAR Information
APAR number
IZ22262
Reported component name
NETCOOL SYS SVC
Reported component ID
5724P4300
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-05-13
Closed date
2008-05-30
Last modified date
2009-01-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
NETCOOL SYS SVC
Fixed component ID
5724P4300
Applicable component levels
R400 PSY
UP
Document Information
Modified date:
05 January 2009