Error description
If you try to add a new parent master category to a catalog entry that has an existing parent master category, the following validation exception is thrown: Exception message: The Catalog entry <CATENTRY_NAME> - Catalog group <NEW_CATGROUP_NAME> relationship cannot be created, because the catalog entry already belongs to a catalog group <CURRENT_CATGROUP_NAME> in the master catalog. Remove the existing relationship before creating a new catalog group relationship for the catalog entry.
Local fix
Delete existing parent master category before you load the new data with the Data Load utility.
Problem summary
USERS AFFECTED: WebSphere Commerce Version 7 and Version 8. PROBLEM ABSTRACT: Cannot change a catalog entry's master category relationship using the Data Load utility BUSINESS IMPACT: Users cannot change a catalog entry's parent master category without deleting existing parent master category first. RECOMMENDATION:
Problem conclusion
Added a new property "replaceParentMasterCategory" for com.ibm.commerce.catalog.dataload.mediator.CatalogEntryMediator and com.ibm.commerce.catalog.dataload.mediator.CatalogEntryParentCat alogGroupMediator. If you want to allow the Data Load utility to overwrite the existing parent master category of a catalog entry without throwing a validation error, set the property value to "true" in the following files: - wc-loader-catalog-entry-parent-catalog-group.xml - wc-loader-catalog-entry.xml For more information, see - WebSphere Commerce Version 7: http://www.ibm.com/support/knowledgecenter/SSZLC2_7.0.0/com.ibm. commerce.install.doc/tasks/tig_JR55608.htm.
Temporary fix
Comments
APAR Information
APAR number
JR55608
Reported component name
WC BUS EDITION
Reported component ID
5724I3800
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-23
Closed date
2016-04-29
Last modified date
2016-04-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WC BUS EDITION
Fixed component ID
5724I3800
Applicable component levels
R700 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYSYL","label":"WebSphere Commerce Enterprise"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Line of Business":{"code":"LOB31","label":"WCE Watson Marketing and Commerce"}}]