Fixes are available
APAR status
Closed as program error.
Error description
In-memory reference for the UCA data mapping not getting updated during cloning results in validation error. Following validaton errors is shown from service with invoke UCA steps that have data mappings: No Input paramter mapping found for parameter without default.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users cloning process applications or * * toolkits containing services with Invoke * * UCA steps that have data mappings. * **************************************************************** * PROBLEM DESCRIPTION: Parameter mapping validation errors * * appear on services with Invoke UCA * * steps after cloning. * **************************************************************** * RECOMMENDATION: * **************************************************************** An id used to look up parameter mappings in the Invoke UCA step is not updated during cloning so it continues to use the original id. Validation generates an error when it tries to look up the parameter mapping with the new id for the clone. This id reference is not persisted but validation must be triggered again to clear the error.
Problem conclusion
The id in question is updated when the other dependencies are updated during the cloning process. Install/Dependency information is available in the readme.txt on FixCentral. When the user goes to the download files page in FixCentral, the readme.txt will be available with the interim fix package as a separate download.
Temporary fix
Edit the service and make an insignificant change to trigger validation. The parameter mapping can now be found with the new id so the validation error is resolved.
Comments
APAR Information
APAR number
JR47573
Reported component name
BPM ADVANCED
Reported component ID
5725C9400
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-08-21
Closed date
2013-10-23
Last modified date
2013-10-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BPM ADVANCED
Fixed component ID
5725C9400
Applicable component levels
R800 PSY
UP