APAR status
Closed as program error.
Error description
If a sequence has an abort and is in status "Aborted/Restartable" it is not possible to restart it from the Designer. The Designer always gives the following message: "The job 'xy' is not in a runnable state, it may need to be recompiled. Its current state is aborted." However, when you use the Director, you can restart the sequence without any problems.
Local fix
Problem summary
User affected Designer can't start sequences in status Aborted/Restartable. Problem Description Designer can't start sequences in status Aborted/Restartable. This works with Director.
Problem conclusion
Fix the issue by checking the job's restartable status.
Temporary fix
Comments
APAR Information
APAR number
JR46534
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
870
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-05-03
Closed date
2013-05-29
Last modified date
2013-05-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R870 PSY
UP
R910 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.7","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: