A fix is available
APAR status
Closed as program error.
Error description
Data is being corrupted when moved between different data types without issuing a warning Justification A customer has no way to know when DS is corrupting data today in these situations. We need to more proactively allow them to handle this scenario.
Local fix
No workaround is suggested
Problem summary
**************************************************************** USERS AFFECTED: Transformer, Lookup, or Slowly Changing Dimension stages in Parallel jobs where data may be assigned to an output data field that cannot contain it. **************************************************************** PROBLEM DESCRIPTION: In a Transformer, Lookup, or Slowly Changing Dimension stage of a Parallel job, input data may be assigned to an output data field that cannot contain it. For example, a field of type Integer may be derived from a BigInt. There are also cases where an arithmetic expression involving non-numeric fields uses an intermediate variable to do string-to-number and number-to-string conversion, leading to loss of precision owing to the data type used for the intermediate variable. At run time, data that would overflow the output field is truncated or modified to fit, without a warning being logged by the Transform operator. So for example an integer that is too large for the destination may become negative. **************************************************************** RECOMMENDATION: Apply the patch for JR46434. Refer to TechNote: http://www.ibm.com/support/docview.wss?uid=swg21639629 ****************************************************************
Problem conclusion
This change addresses the issue where implicit type conversion might lead to data loss, but no warnings are issued to warn a user that this may occur. The function of the change is to: - Generate compile-time warnings for potential data loss caused by implicit type conversions that are detected in expression. - Log a message at job runtime if such warnings have been generated, including the message contents. - Provide an option to disable the generation of warnings at compile time and logging these at run time. The change will cause a warning file to be written a job?s RT_SCnn folder if certain type conversion issues are detected in the Transformer, Lookup or Slowly Changing Dimension stages. This will only happen if the environment variable APT_TRANSFORM_RANGE_CHECK is set to 1 at compile time. Setting APT_TRANSFORM_RANGE_CHECK=0, or not defining that variable at all, means the warning files are not produced.
Temporary fix
Comments
APAR Information
APAR number
JR46434
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-04-24
Closed date
2013-06-14
Last modified date
2013-06-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CLIENT SERVER
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R850 PSY
UP
R870 PSY
UP
R910 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"InfoSphere DataStage"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Line of Business":{"code":"LOB10","label":"Data and AI"}}]