Fixes are available
APAR status
Closed as program error.
Error description
ICONV("マsa","S") is returning ?00 in the DataStage job if the 1st character is not between A-Z or a-z.
Local fix
Problem summary
In DataStage server jobs, the SOUNDEX and ICONV with S code functions in BASIC transformer stages can return unmappable strings when the first character in the data is not between A-Z or a-z.
Problem conclusion
Introduced an environment variable DSE_SOUNDEX_BEHAVIOR. When set to 1, an empty string will be returned from soundex if the first character is not A-Z or a-z.
Temporary fix
Comments
APAR Information
APAR number
JR45592
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
810
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-01-31
Closed date
2013-02-15
Last modified date
2013-02-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R810 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
15 February 2013